IEC 61347-2-9:2000
Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps)

Std & Spec
Standard No.
IEC 61347-2-9:2000
Release Date
2000
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
IEC 61347-2-9:2003
Lastest
IEC 61347-2-9:2012
Replace
IEC 34C/506/FDIS:2000 IEC 60922:1997
Scope
This part of IEC 61347 specifies particular safety requirements for ballasts for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-type ballasts for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This standard applies to complete ballasts and to their component parts such as reactors, transformers and capacitors. Particular requirements for thermally protected ballasts are given in annex B. NOTE 1 For certain types of discharge lamps, an ignitor is required. NOTE 2 Ballasts for fluorescent lamps are covered by IEC 61347-2-8. Performance requirements are the subject of IEC 60923.

IEC 61347-2-9:2000 history

  • 2012 IEC 61347-2-9:2012 Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)
  • 2009 IEC 61347-2-9:2009 Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps)
  • 1970 IEC 61347-2-9:2000/AMD2:2006 Amendment 2 - Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps)
  • 1970 IEC 61347-2-9:2000/AMD1:2003 Amendment 1 - Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps)
  • 2003 IEC 61347-2-9:2003 Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps)
  • 2000 IEC 61347-2-9:2000 Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps)

IEC 61347-2-9:2000 Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) has been changed from IEC 60922:1997 Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - General and safety requirements.




Copyright ©2024 All Rights Reserved