The provisions of this part of GB 3836 are applicable to users, and the content it contains is related to the inspection and maintenance of electrical installations used in hazardous locations. The hazards of this hazardous location may be caused by flammable gases. Roll caused. This section does not include: --- other basic installation and inspection requirements for electrical equipment; --- verification of electrical equipment; --- repair and restoration of explosion-proof equipment (see IEC60079-19). This part is a supplement to the requirements of IEC60364-6. In the case of dust fibers and flying flocs, the cleanliness of site cleaning may have an impact on inspection and maintenance requirements. This section applies to the mixture of explosive gas or dust and air under atmospheric conditions, or the place where a layer of combustible powder appears to cause danger. This section does not apply to --- underground coal mines; --- places where heterogeneous mixtures cause danger --- explosive dust that burns without oxygen in the atmosphere. spontaneous combustion substances.
GB/T 3836.16-2017 Referenced Document
IEC 60079-0 Interpretation Sheet 2 - Explosive atmospheres - Part 0: Equipment - General requirements*, 2019-06-27 Update
IEC 60079-1 Interpretation sheet 1 - Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"*, 2020-05-28 Update
IEC 60079-2 Explosive atmospheres - Part 0: Equipment - General requirements*, 2024-04-22 Update
IEC 60079-7 Atmosphères explosives – Partie 7: Protection du matériel par sécurité augmentée ?e? (Edition 5.1; Consolidated Reprint)
IEC 60364-6 Low voltage electrical installations - Part 6: Verification; Corrigendum 1
IEC 61241 Electrical apparatus for use in the presence of combustible dust - Part 4: Type of protection "pD"
IEC 61241-1 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
IEC 61241-14:2004 Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation
IEC 61241-4 Electrical apparatus for use in the presence of combustible dust - Part 4: Type of protection "pD"
GB/T 3836.16-2017 history
2022GB/T 3836.16-2022 Explosive atmospheres—Part 16: Electrical installations inspection and maintenance
2017GB/T 3836.16-2017 Explosive atmospheres―Part 16: Electrical installations inspection and maintenance
2006GB 3836.16-2006 Electrical apparatus for explosive gas atmospheres.Part 16:Inspection and maintenance of electrical installation(other than mines)
GB/T 3836.16-2017 Explosive atmospheres―Part 16: Electrical installations inspection and maintenance has been changed from GB 3836.16-2006 Electrical apparatus for explosive gas atmospheres.Part 16:Inspection and maintenance of electrical installation(other than mines).