German construction contract procedures (VOB) - Part C: General technical specifications in construction contracts (ATV) - Waterproofing
1Key Takeaways
DIN 18336 Waterproofing Project " Suitable for waterproofing using asphalt membranes, bituminous materials and metal strips, as well as plastic and elastomer membranes, to prevent ground moisture, non-stagnant and stagnant water seepage, and non-pressure and pressure water, including the production of necessary insulat…
2Scope / Description
DIN 18336 Waterproofing Project " Suitable for waterproofing using asphalt membranes, bituminous materials and metal strips, as well as plastic and elastomer membranes, to prevent ground moisture, non-stagnant and stagnant water seepage, and non-pressure and pressure water, including the production of necessary insulation layers, isolation layers, separation layers and protective layers. It is also suitable for waterproofing under dense greening. DIN 18336 Not suitable for:
——High impermeability concrete (see DIN 18331 Concrete Engineering " ) - Roof waterproofing (see DIN 18338 Roof covering and roof waterproofing works " ) and extensive green roof surface waterproofing - Asphalt pouring works (see DIN 18354 Asphalt pouring project " ) - Waterproofing of bridge carriageway slabs belonging to public roads -Waterproofing of landfills, earthworks and structures constructed using closed construction methods - Suitable for supplementary waterproofing of wet areas affected by splashing water in residential buildings DIN 18299 General provisions for various types of construction projects " No. 1 to 5 In case of any conflict, DIN 18336 The provisions of the