nsBAS EN 17671:2026
ISBIH · 2026

Heating systems and water-based cooling systems in buildings - Design for water-based cooling systems

1Key Takeaways

This document specifies design criteria for closed water-based cooling systems in buildings and the design of such systems is described. The definitions are aimed at achieving an appropriate level of technical quality and maintaining the desired thermal indoor climate with minimum energy consumption. This document doe…

2Scope / Description

This document specifies design criteria for closed water-based cooling systems in buildings and the design of such systems is described. The definitions are aimed at achieving an appropriate level of technical quality and maintaining the desired thermal indoor climate with minimum energy consumption.
This document does not apply to systems for dissipating process heat from industrial processes. It also does not apply to and does not amend product standards or product installation requirements.
This document is applicable to cooling systems of the following type (see also Figure 1):
1) devices for the water-based heat rejection of the chilling system;
2) devices for chilling and storage of chilled water;
3) devices for the distribution of chilled water;
4) devices for the absorption of heat ("cooling emission");
5) control devices;
6) safety devices.

Figure 1 - Schematic example of a water-based cooling system

This document does not cover additional safety aspects for water-based cooling systems with local operating temperatures ≤ 0 °C. The other clauses of this document are still valid for systems with local operating temperatures ≤ 0 °C.
This document also does not cover the chilling system itself, but only the parts of the chilling system which are an integral part of the cooling system, including determination of the design performance. Furthermore, this document does not cover:
- the requirements for installation or instructions for operation, maintenance and use;
- the design of the system components (e.g. recooler, chilling system, coolers, pipes, safety devices etc.).

3Version History

5Citation Network

0
Cite this standard
0
Referenced herein

6Frequently Asked Questions

What is nsBAS EN 17671:2026?
nsBAS EN 17671:2026 — Heating systems and water-based cooling systems in buildings - Design for water-based cooling systems is an international standard developed by Institute for Standardization of Bosnia and Herzegovina. This document specifies design criteria for closed water-based cooling systems in buildings and the design of such systems is described. The definitions are aimed at achieving an appropriate level of technical quality and maintaining the desired...
What does nsBAS EN 17671:2026 cover?
This standard covers: This document specifies design criteria for closed water-based cooling systems in buildings and the design of such systems is described. The definitions are aimed at achieving an appropriate level of technical quality and maintaining the desired thermal indoor climate with minimum energy...
Who should use this standard?
This standard is intended for organizations, professionals, and stakeholders involved in various industries and sectors. It is applicable to manufacturers, service providers, regulatory bodies, and certification organizations.
What is the latest version of nsBAS EN 17671:2026?
The current published version is nsBAS EN 17671:2026, published on 2026. Always check for amendments or pending revisions.
How do I purchase nsBAS EN 17671:2026?
You can purchase nsBAS EN 17671:2026 by visiting our contact page. Click "Get This Standard" to view pricing and send a purchase inquiry. Our team will respond with payment and delivery details.