ASTM E1996-23
ASTM · 2023-08-04

Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes

试验/规范 Replaced ICS 91.060.10 ICS 91.060.50 Cited by 1

1Key Takeaways

1.1  This specification covers exterior windows, glazed curtain walls, doors, and impact protective systems used in buildings located in geographic regions that are prone to hurricanes. 1.1.1  Exception— Exterior garage doors and rolling doors are governed by ANSI/DASMA 115 and are beyond the scope of this specificati…

2Scope / Description

1.1  This specification covers exterior windows, glazed curtain walls, doors, and impact protective systems used in buildings located in geographic regions that are prone to hurricanes. 1.1.1  Exception— Exterior garage doors and rolling doors are governed by ANSI/DASMA 115 and are beyond the scope of this specification. 1.2  This specification provides the information required to conduct Test Method E1886 . 1.3  Qualification under this specification provides a basis for judgment of the ability of applicable elements of the building envelope to remain unbreached during a hurricane; thereby minimizing the damaging effects of hurricanes on the building interior and reducing the magnitude of internal pressurization. While this standard was developed for hurricanes, it may be used for other types of similar windstorms capable of generating windborne debris. 1.4  This specification provides a uniform set of guidelines based upon currently available information and research.2 As new information and research becomes available it will be considered. 1.5  All values are stated in SI units and are to be regarded as standard. Values given in parentheses are for information only. Where certain values contained in reference documents cited and quoted herein are stated in inch-pound units, they must be converted by the user. 1.6  The following precautionary statement pertains only to the test method portion, Section 5 , of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

3Version History

ASTM E1996-01 older 2001
ASTM E1996-02 older 2002
ASTM E1996-03 older 2003
ASTM E1996-04 older 2004-05-01
ASTM E1996-05 older 2005
ASTM E1996-05a older 2005
ASTM E1996-05b older 2005
ASTM E1996-06 older 2006
ASTM E1996-08 older 2008
ASTM E1996-08e1 older 2008
ASTM E1996-08e2 older 2008
ASTM E1996-09 older 2009
ASTM E1996-12 older 2012
ASTM E1996-12a older 2012
ASTM E1996-14 older 2014
ASTM E1996-14a older 2014-10-01
ASTM E1996-17 older 2017
ASTM E1996-20 older 2020-09-01
ASTM E1996-23 2023-08-04
ASTM E1996-26 newer 2026-06-15

5Citation Network

1
Cite this standard
7
Referenced herein
ANSI/DASMA 115 ASCE/SEI 7 ASTM C1135 ASTM C719 ASTM D3575 ASTM E1886 ASTM E631

6Frequently Asked Questions

What is ASTM E1996-23?
ASTM E1996-23 — Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes is an international standard developed by American Society for Testing and Materials (ASTM). 1.1  This specification covers exterior windows, glazed curtain walls, doors, and impact protective systems used in buildings located in geographic regions that are prone to hurricanes. 1.1.1  Exception— Exterior garage doors and rolling doors are...
What does ASTM E1996-23 cover?
This standard covers: 1.1  This specification covers exterior windows, glazed curtain walls, doors, and impact protective systems used in buildings located in geographic regions that are prone to hurricanes. 1.1.1  Exception— Exterior garage doors and rolling doors are governed by ANSI/DASMA 115 and are beyond the scope...
Who should use this standard?
This standard is intended for organizations, professionals, and stakeholders involved in various industries and sectors. It is applicable to manufacturers, service providers, regulatory bodies, and certification organizations.
What is the latest version of ASTM E1996-23?
The current published version is ASTM E1996-23, published on 2023-08-04. Always check for amendments or pending revisions.
How do I purchase ASTM E1996-23?
You can purchase ASTM E1996-23 by visiting our contact page. Click "Get This Standard" to view pricing and send a purchase inquiry. Our team will respond with payment and delivery details.