NB/T 11630-2024
NB · 2024-09-24

Pipeline water flow monitor for coal mines

规范 ICS 73.100.99

1Key Takeaways

This document applies to the design, manufacture and inspection of flow monitoring instruments used to measure pipeline water volume underground in coal mines.

2Expert Interpretation

In-depth interpretation of the NB/T 11630-2024 standard for pipeline water flow monitors for coal mines, covering explosion-proof design, technical parameters, test methods and inspection rules. Analyze key indicators such as flow measurement range 0.05-180m³/h, error ±2%, and provide application specifications for intrinsically safe equipment in methane environments.

Analysis of the core technical requirements of the standard

Technical dimensions Requirements of this standard Comparison with conventional industrial standards
Explosion-proof grade Ex ib I Mb/Ex ia I Ma Usually Ex d IIB
Flow measurement error ≤±2% Usually±3%~5%
Ambient temperature -5℃~40℃ Usually0℃~50℃

Detailed explanation of key technical indicators

The nominal diameter of the sensor of the pipeline water flow monitor for coal mines needs to be selected in the range of 15mm~150mm, and its core performance requirements include:

  • Flow repeatability error ≤±1%
  • Intrinsically safe terminal insulation resistance ≥10MΩ
  • Enclosure protection grade ≥IP54

Key points of explosion-proof safety design

According to GB/T3836.1-2021 standard, special attention should be paid to explosion-proof design:

  1. The operating parameters of components shall not exceed 2/3 of the rated value
  2. The maximum surface temperature shall be ≤150℃
  3. The non-metallic housing shall pass the surface insulation resistance test

Implementation suggestions and precautions

Installation specification: The sensor should be installed in the middle of the straight pipe section, ensuring that the straight pipe section length is 10D in front and 5D in the back (D is the pipe diameter)

Maintenance cycle: It is recommended to perform insulation resistance test every 6 months and flow calibration every year

3Version History

NB/T 11630-2024 2024-09-24

5Citation Network

0
Cite this standard
15
Referenced herein
AQ 1043 GB/T 10111 GB/T 1047 GB/T 191 GB/T 2423.1-2008 GB/T 2423.10-2019 GB/T 2423.2 GB/T 2423.4

6Frequently Asked Questions

What is NB/T 11630-2024?
NB/T 11630-2024 — Pipeline water flow monitor for coal mines is an international standard developed by Professional Standard - Energy. This document applies to the design, manufacture and inspection of flow monitoring instruments used to measure pipeline water volume underground in coal mines.
What does NB/T 11630-2024 cover?
This standard covers: This document applies to the design, manufacture and inspection of flow monitoring instruments used to measure pipeline water volume underground in coal mines.
Who should use this standard?
This standard is intended for organizations, professionals, and stakeholders involved in various industries and sectors. It is applicable to manufacturers, service providers, regulatory bodies, and certification organizations.
What is the latest version of NB/T 11630-2024?
The current published version is NB/T 11630-2024, published on 2024-09-24. Always check for amendments or pending revisions.
How do I purchase NB/T 11630-2024?
You can purchase NB/T 11630-2024 by visiting our contact page. Click "Get This Standard" to view pricing and send a purchase inquiry. Our team will respond with payment and delivery details.