GB/T 17467-2020
GB · 2020-03-31

High-voltage/low-voltage prefabricated substation

规范 Cited by 7

1Key Takeaways

This standard specifies the requirements for the service conditions, ratings, design and structure, type test and delivery test of high-voltage/low-voltage or low-voltage/high-voltage prefabricated substations. This standard applies to prefabricated substations with a rated AC voltage of 3.6kV~40.5kV on the high voltag…

2Scope / Description

This standard specifies the requirements for the service conditions, ratings, design and structure, type test and delivery test of high-voltage/low-voltage or low-voltage/high-voltage prefabricated substations. This standard applies to prefabricated substations with a rated AC voltage of 3.6kV~40.5kV on the high voltage side, including one or more transformers, operating frequency of 50 Hz or below, and installed outdoors in places that are accessible to the public and provide personnel protection. Note 1: The prefabricated substation is connected to the grid through cables and can be operated from its inside (entry type) or outside (non-entry type). For prefabricated substations connected to the grid through overhead lines, this standard can be referred to. Note 2: For prefabricated substations with rated voltage higher than 40.5kV, this standard can be referred to. Note 3: Pre-installed substations for charging piles, pre-installed substations for shore power, pre-installed photovoltaic substations, pre-installed wind power substations, pre-installed substations for traction, etc., can refer to this standard. See Appendix B for more detailed requirements for photovoltaic prefabricated substations. Note 4: For prefabricated substations installed indoors, this standard can be referred to. Prefabricated substations can be installed above ground, partly or fully below ground. The prefabricated substation consists of an enclosure and at least the following main electrical components: ——power transformer; ——high voltage and low voltage switchgear and control equipment; ——high voltage and low voltage internal connections; ——auxiliary equipment and circuits, etc. .

3Version History

GB/T 17467-1998 older 1998-08-17
GB/T 17467-2010 older 2010-09-02
GB/T 17467-2020 2020-03-31

6Frequently Asked Questions

What is GB/T 17467-2020?
GB/T 17467-2020 — High-voltage/low-voltage prefabricated substation is an international standard developed by General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China. This standard specifies the requirements for the service conditions, ratings, design and structure, type test and delivery test of high-voltage/low-voltage or low-voltage/high-voltage prefabricated substations. This standard applies to prefabricated...
What does GB/T 17467-2020 cover?
This standard covers: This standard specifies the requirements for the service conditions, ratings, design and structure, type test and delivery test of high-voltage/low-voltage or low-voltage/high-voltage prefabricated substations. This standard applies to prefabricated substations with a rated AC voltage of...
Who should use this standard?
This standard is intended for organizations, professionals, and stakeholders involved in various industries and sectors. It is applicable to manufacturers, service providers, regulatory bodies, and certification organizations.
What is the latest version of GB/T 17467-2020?
The current published version is GB/T 17467-2020, published on 2020-03-31. Always check for amendments or pending revisions.
How do I purchase GB/T 17467-2020?
You can purchase GB/T 17467-2020 by visiting our contact page. Click "Get This Standard" to view pricing and send a purchase inquiry. Our team will respond with payment and delivery details.