This part of IEC 61243 is applicable to portable voltage detectors with or without a built-in power source to be used on electrical systems for voltages of 1 kV to 36 kV a.c., and frequencies from 15 Hz to 60 Hz. This part applies only to resistive voltage detectors used in contact with the part to be tested, as a sing…

2Scope / Description

This part of IEC 61243 is applicable to portable voltage detectors with or without a built-in power source to be used on electrical systems for voltages of 1 kV to 36 kV a.c., and frequencies from 15 Hz to 60 Hz.
This part applies only to resistive voltage detectors used in contact with the part to be tested, as a single unit or as a separate device completed by an adaptable insulating pole covered in IEC 60855 or IEC 61235. Other types of voltage detectors are not covered by this part of standard. Capacitive voltage detectors are covered in IEC 61243-1.
The upper voltage limit is in accordance with the tests described in this part of IEC 61243.
Some restrictions on their use are applicable in the case of factory-assembled switchgear and on overhead systems of electrified railways (see annex B).
NOTE 1 Except when otherwise specified, all the voltages defined in this standard refer to phase-to-phase voltages of three-phase systems. Resistive detectors may be used in other than three-phase systems, but the applicable phase-to-phase or phase-to-earth (ground) voltage shall be used to determine the operating voltage.
NOTE 2 Although this standard does not cover d.c. voltage detectors, some detectors may respond to d.c. voltage.

3Version History

IEC 61243-2:1995 older 1995-10
IEC 61243-2:1995/COR1:1996 Cor 1/1996 older 1996-06-01
IEC 61243-2:1995/AMD1:1999 Amd 1/1999 older 2000-03-30
IEC 61243-2:1995/COR2:1999 Cor 2/1999 older 1999-07
IEC 61243-2:1995/COR3:2000 Cor 3/2000 older 2000-03
IEC 61243-2:1995/AMD2:2002 Amd 2/2002 newer 2002-04
IEC 61243-2:2002 newer 2002-06

5Citation Network

0
Cite this standard
0
Referenced herein

6Frequently Asked Questions

What is IEC 61243-2:2000?
IEC 61243-2:2000 — Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c. is an international standard developed by International Electrotechnical Commission (IEC). This part of IEC 61243 is applicable to portable voltage detectors with or without a built-in power source to be used on electrical systems for voltages of 1 kV to 36 kV a.c., and frequencies from 15 Hz to 60 Hz. This part applies only to resistive...
What does IEC 61243-2:2000 cover?
This standard covers: This part of IEC 61243 is applicable to portable voltage detectors with or without a built-in power source to be used on electrical systems for voltages of 1 kV to 36 kV a.c., and frequencies from 15 Hz to 60 Hz. This part applies only to resistive voltage detectors used in contact with the part to...
Who should use this standard?
This standard is intended for organizations, professionals, and stakeholders involved in various industries and sectors. It is applicable to manufacturers, service providers, regulatory bodies, and certification organizations.
What is the latest version of IEC 61243-2:2000?
The current published version is IEC 61243-2:2000, published on 2000-03. Always check for amendments or pending revisions.
How do I purchase IEC 61243-2:2000?
You can purchase IEC 61243-2:2000 by visiting our contact page. Click "Get This Standard" to view pricing and send a purchase inquiry. Our team will respond with payment and delivery details.