ASTM E2232-10
ASTM · 2010

Standard Guide for Selection and Use of Mathematical Methods for Calculating Absorbed Dose in Radiation Processing Applications

指南 Replaced ICS 17.240 Cited by 3

1Key Takeaways

Use as an Analytical Tool8212;Mathematical methods provide an analytical tool to be employed for many applications related to absorbed dose determinations in radiation processing. Mathematical calculations may not be used as a substitute for routine dosimetry in some applications (for example, medical device sterilizat…

2Scope / Description

Use as an Analytical Tool8212;Mathematical methods provide an analytical tool to be employed for many applications related to absorbed dose determinations in radiation processing. Mathematical calculations may not be used as a substitute for routine dosimetry in some applications (for example, medical device sterilization, food irradiation).

Dose Calculation8212;Absorbed-dose calculations may be performed for a variety of photon/electron environments and irradiator geometries.

Evaluate Process Effectiveness8212;Mathematical models may be used to evaluate the impact of changes in product composition, loading configuration, and irradiator design on dose distribution.

Complement or Supplement to Dosimetry8212;Dose calculations may be used to establish a detailed understanding of dose distribution, providing a spatial resolution not obtainable through measurement. Calculations may be used to reduce the number of dosimeters required to characterize a procedure or process (for example, dose mapping).

Alternative to Dosimetry8212;Dose calculations may be used when dosimetry is impractical (for example, granular materials, materials with complex geometries, material contained in a package where dosimetry is not practical or possible).

Facility Design8212;Dose calculations are often used in the design of a new irradiator and can be used to help optimize dose distribution in an existing facility or radiation process. The use of modeling in irradiator design can be found in references (3-9).

Validation8212;The validation of the model should be done through comparison with reliable and traceable dosimetric measurements. The purpose of validation is to demonstrate that the mathematical method makes reliable predictions of dose and other transport quantities. Validation compares predictions or theory to the results of an appropriate experiment. The degree of validation is commensurate with the application. Guidance is given in the documents referenced in Annex A2.

Verification8212;Verification is the confirmation of the mathematical correctness of a computer implementation of a mathematical method. This can be done, for example, by comparing numerical results with known analytic solutions or with other computer codes that have been previously verified. Verification should be done to ensure that the simulation is appropriate for the intended application. Refer to 3.1.23.1.

Note 28212;Certain applications of the mathematical model deal with Operational Qualification (OQ), Performance Qualification (PQ) and process control in radiation processing such as the sterilization of healthcare products. The application and use of the mathematical model in these applications may have to meet regulatory requirements. Refer to Section 6 for prerequisites for application of a mathematical method and Section 8 for requirements before routine use of the mathematical method.

Uncertainty8212;An absorbed dose prediction should be accompanied by an estimate of overall uncertainty, as it is with absorbed-dose determination (refer to ISO/ASTM 51707 and NIST Technical Note 1297). In many cases, absorbed-dose measurement helps to establish the uncertainty in the dose calculation.

This guide should not be used as the only reference in the selection and use of mathematical models. The user is encoura......

3Version History

ASTM E2232-02 older 2002
ASTM E2232-16 newer 2016-12-01
ASTM E2232-20 newer 2020-12-01
ASTM E2232-21 newer 2021-06-15
ASTM E2232-21e1 newer 2021-06-15
ASTM E2232-26 newer 2026-05-01

6Frequently Asked Questions

What is ASTM E2232-10?
ASTM E2232-10 — Standard Guide for Selection and Use of Mathematical Methods for Calculating Absorbed Dose in Radiation Processing Applications is an international standard developed by American Society for Testing and Materials (ASTM). Use as an Analytical Tool8212;Mathematical methods provide an analytical tool to be employed for many applications related to absorbed dose determinations in radiation processing. Mathematical calculations may not be used as a substitute for routine...
What does ASTM E2232-10 cover?
This standard covers: Use as an Analytical Tool8212;Mathematical methods provide an analytical tool to be employed for many applications related to absorbed dose determinations in radiation processing. Mathematical calculations may not be used as a substitute for routine dosimetry in some applications (for example,...
Who should use this standard?
This standard is intended for organizations, professionals, and stakeholders involved in various industries and sectors. It is applicable to manufacturers, service providers, regulatory bodies, and certification organizations.
What is the latest version of ASTM E2232-10?
The current published version is ASTM E2232-10, published on 2010. Always check for amendments or pending revisions.
How do I purchase ASTM E2232-10?
You can purchase ASTM E2232-10 by visiting our contact page. Click "Get This Standard" to view pricing and send a purchase inquiry. Our team will respond with payment and delivery details.