DIN EN 61837-3:2016
DIN · 2016-04

Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 3: Metal enclosures (IEC 61837-3:2015); German version EN 61837-3:2015

Replaced ICS 31.240

1Key Takeaways

This part of IEC 61837 deals with standard package dimensions and terminals for surface-mount devices (SMDs) used for frequency stabilization and selection in metal packages. It is based on IEC 61240, which standardizes design rules for package drawings of surface-mount devices.

2Expert Interpretation

An in-depth look at the DIN EN 61837-3:2016-04 standard, covering key technical requirements for surface mounting of metal-encased piezoelectric devices, including specifications, dimensional requirements, and terminal connections. This standard applies to surface-mount devices for frequency control and selection, providing detailed guidance on dimensional tolerances and structural configurations.

Standard Overview and Technical Background

DIN EN 61837-3:2016-04 is an international standard adopted by the European Committee for Electrotechnical Standardization (CENELEC) on May 20, 2015, and officially implemented on April 1, 2016. This standard replaces the 2001 version and provides standardized dimensions and terminal connection specifications for metal housings of surface-mounted piezoelectric devices.

Main technical changes and evolutions

Compared with DIN EN 61837-3:2001-09 version, the new version of the standard has made a number of important technical revisions:

Changed items Requirements of the 2001 version Requirements of the 2016 version Technical significance
Shell drawing perspective Right view optional Must include four views: top view, front view, right view, bottom view Improve drawing completeness and manufacturing accuracy
Height marking Use shell height Use the total height symbol G or G with subscript number Unified dimensioning system
Terminal spacing No clear regulations Must be marked center to center, with a reference dimension of 2.54n mm or 1.27n mm Improve installation compatibility
Connection surface size Mark minimum value Mark maximum value Simplify consumer use

Metal shell configuration and classification

The standard defines a special surface mounting structure configuration, using SMS (Surface-Mounted, Special) as the identifier. The shell structure is divided into the following types according to the terminal type:

  • L-type structure: Structure with bent terminals
  • J-type structure: Structure with bent terminals (no identification for leadless versions)

The model name adopts a four-part structure: configuration symbol (SMS), lead structure (L/J), number of terminals, and two-digit serial number.

Dimension specifications and tolerance requirements

The standard specifies the key dimensional parameters of metal housings in detail:

Parameter symbol Description Benchmark requirements Applicable conditions
G Total height Indication with subscript numbers Different height versions
e Terminal spacing 2.54n mm or 1.27n mm Use 1.27n when shell size is <6mm
F Length dimension Numbers with Subscripts Various Length Versions

Terminal Connection and Wiring Specifications

Due to the unique SMD design of the SMS housing, the standard does not prescribe a uniform terminal assignment. The specific terminal configuration must be clearly stated in the product specification according to customer requirements. This flexibility allows manufacturers to optimize the configuration based on the specific characteristics of the piezoelectric device.

Recommendations for the implementation of the standard

Precautions in the design phase

During the product design phase, engineers should pay special attention to the following:

  • Prepare housing drawings in strict accordance with the four views specified in the standard
  • Terminal spacing must be marked center-to-center
  • For housings with multiple heights, use subscripts such as G1 and G2
  • Use maximum values instead of minimum values for connection surface dimensions

Manufacturing and quality control

Key points for quality control in the production process:

  • Ensure that the resistance welding process meets the standard requirements
  • The dimensional tolerance of the metal housing must be strictly controlled within the specified range
  • The terminal bending molding process needs to ensure consistency and reliability
  • For the J-type structure of the plastic carrier, pay attention to the matching of the thermal expansion coefficient of the materials

Transition period management

The standard sets a transition period until May 20, 2018. Enterprises should:

  • Complete the technical conversion from the 2001 version to the 2016 version as soon as possible
  • Update relevant design specifications and inspection standards
  • Conduct compliance assessments for existing products
  • Train technical personnel to master the requirements of the new standard

Application Areas and Market Impact

This standard applies to a variety of electronic equipment that requires frequency stability and selection, including:

  • Frequency control modules for communication equipment
  • Timing and synchronization systems in automotive electronics
  • Precise clock sources for industrial control equipment
  • High-stability oscillators for medical electronic equipment

The unified implementation of the standard will promote the interchangeability and reliability of surface mount piezoelectric devices, reduce manufacturing costs, and improve product quality consistency.

Technology Development Trends

As electronic devices develop towards miniaturization and high frequency, the technical requirements for surface-mounted piezoelectric devices continue to increase:

  • The housing size is further reduced, requiring higher manufacturing precision
  • High-frequency applications pose new challenges to terminal connection reliability
  • Multi-chip packaging technology requires more flexible housing design
  • Thermal management requirements promote the application of new materials and new structures

DIN EN 61837-3:2016-04 provides a standardized basis for these technological developments, ensuring compatibility and reliability between products from different manufacturers.

3Version History

DIN EN 61837-3:2013 older
DIN EN 61837-3:2001 older 2001-09
DIN EN 61837-3:2001-09 older 2001-09-01
DIN EN 61837-3 E:2013 Amd E/2013-01 older 2013-05-01
DIN EN 61837-3 E:2013-05 Amd E/2013-05 older 2013-05
DIN EN 61837-3:2016-04 newer 2016-04

5Citation Network

0
Cite this standard
17
Referenced herein
IEC 60122-2-1983 IEC 60122-3-2010 IEC 60191-6-2009 IEC 60368-1 AMD 1-2004 IEC 60368-1-2000 IEC 60368-2-1-1988 IEC 60368-2-2-1996 IEC 60368-3-2010

6Frequently Asked Questions

What is DIN EN 61837-3:2016?
DIN EN 61837-3:2016 — Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 3: Metal enclosures (IEC 61837-3:2015); German version EN 61837-3:2015 is an international standard developed by German Institute for Standardization. This part of IEC 61837 deals with standard package dimensions and terminals for surface-mount devices (SMDs) used for frequency stabilization and selection in metal packages. It is based on IEC 61240, which standardizes design rules for package...
What does DIN EN 61837-3:2016 cover?
This standard covers: This part of IEC 61837 deals with standard package dimensions and terminals for surface-mount devices (SMDs) used for frequency stabilization and selection in metal packages. It is based on IEC 61240, which standardizes design rules for package drawings of surface-mount devices.
Who should use this standard?
This standard is intended for organizations, professionals, and stakeholders involved in various industries and sectors. It is applicable to manufacturers, service providers, regulatory bodies, and certification organizations.
What is the latest version of DIN EN 61837-3:2016?
The current published version is DIN EN 61837-3:2016, published on 2016-04. Always check for amendments or pending revisions.
How do I purchase DIN EN 61837-3:2016?
You can purchase DIN EN 61837-3:2016 by visiting our contact page. Click "Get This Standard" to view pricing and send a purchase inquiry. Our team will respond with payment and delivery details.