IEC 61803:2016
IEC · 2016-05

Determination of power losses in high-voltage direct current (HVDC) converter stations with line commutated converters

Replaced ICS 29.200

1Key Takeaways

This International Standard applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange in utility systems. This standard presumes the use of 12-pulse thyristor converters but can, with due care, also be used for 6-pulse thyristor converters. In some applications, synchr…

2Scope / Description

This International Standard applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange in utility systems. This standard presumes the use of 12-pulse thyristor converters but can, with due care, also be used for 6-pulse thyristor converters. In some applications, synchronous compensators or static var compensators (SVC) may be connected to the a.c. bus of the HVDC converter station. The loss determination procedures for such equipment are not included in this standard. This standard presents a set of standard procedures for determining the total losses of an HVDC converter station. Typical HVDC equipment is shown in figure 1. The procedures cover all parts, except as noted above, and address no-load operation and operating losses together with their methods of calculation which use, wherever possible, measured parameters. Converter station designs employing novel components or circuit configurations compared to the typical design assumed in this standard, or designs equipped with unusual auxiliary circuits that could affect the losses, shall be assessed on their own merits.

3Version History

IEC 61803:1999/COR1:1999 Cor 1/1999 older 1999-10
IEC 61803:1999/AMD1:2010 Amd 1/2010 older 2010-11
IEC 61803:2011 older 2011-03
IEC 61803:1999/AMD2:2016 Amd 2/2016 older 2016-05-25
IEC 61803:2016 2016-05
IEC 61803:2020 RLV newer 2020-10-19
IEC 61803:2026 PRV newer 2026-01-30

5Citation Network

0
Cite this standard
6
Referenced herein
IEC 60076-1:1993 IEC 60076-6:2007 IEC 60633:1998 IEC 60700-1:2015 IEC 60747-6:2016 IEC 60871-1:2014

6Frequently Asked Questions

What is IEC 61803:2016?
IEC 61803:2016 — Determination of power losses in high-voltage direct current (HVDC) converter stations with line commutated converters is an international standard developed by International Electrotechnical Commission (IEC). This International Standard applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange in utility systems. This standard presumes the use of 12-pulse thyristor converters but can, with due care, also...
What does IEC 61803:2016 cover?
This standard covers: This International Standard applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange in utility systems. This standard presumes the use of 12-pulse thyristor converters but can, with due care, also be used for 6-pulse thyristor converters. In some...
Who should use this standard?
This standard is intended for organizations, professionals, and stakeholders involved in various industries and sectors. It is applicable to manufacturers, service providers, regulatory bodies, and certification organizations.
What is the latest version of IEC 61803:2016?
The current published version is IEC 61803:2016, published on 2016-05. Always check for amendments or pending revisions.
How do I purchase IEC 61803:2016?
You can purchase IEC 61803:2016 by visiting our contact page. Click "Get This Standard" to view pricing and send a purchase inquiry. Our team will respond with payment and delivery details.