liquid adhesive
1Key Takeaways
This standard specifies the terms and definitions, basic requirements, technical requirements, test methods, inspection rules and markings, packaging, transportation, storage and quality commitment of liquid glue. This standard mainly applies to liquid glue.
2Expert Interpretation
Professional interpretation of Zhejiang Provincial Group Standard T/ZZB 1227-2019 Technical Requirements for Liquid Glues, covering 8 performance indicators such as viscosity and pH value, safety limit requirements for 19 chemical substances, and special test methods such as freeze-thaw cycles and aging resistance. Provide production process control points and test plan design suggestions.
Analysis of the core requirements of the standard
| Technical dimension | Indicator requirements | Test method | Industry comparison |
|---|---|---|---|
| Viscosity | ≥1200 mPa·s | Rotational viscometer (23±2℃) | 20% higher than the national standard for office glue |
| Chemical safety | Migration limits of 18 elements | EN 71-3:2018 | Stricter than EU toy standards |
Key technological breakthroughs
Innovative requirements for the standard liquid glue to pass the -23℃ freeze-thaw cycle test:
- 16 hours of low temperature storage + 8 hours of room temperature recovery
- Adhesion test after 3 cycles
- No cracking of the bottle and no agglomeration of the glue
Implementation suggestions
Production process control
- Establish a DCS system to monitor the glue making temperature curve
- Use an online pH monitor to ensure the 5-8 range
Testing laboratory configuration
| Required equipment | Sharp edge tester, atomic absorption spectrometer |
| Consumables preparation | 80g/m² standard test paper |