IEC 61557-12:2018
IEC · 2018-10-22

Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 12: Power metering and monitoring d

规范 Replaced Cited by 16

1Key Takeaways

This part of IEC 61557 specifies requirements for power metering and monitoring devices (PMD) that measure and monitor the electrical quantities within electrical distribution systems@ and optionally other external signals. These requirements also define the performance in single- and three-phase AC or DC systems havin…

2Scope / Description

This part of IEC 61557 specifies requirements for power metering and monitoring devices (PMD) that measure and monitor the electrical quantities within electrical distribution systems@ and optionally other external signals. These requirements also define the performance in single- and three-phase AC or DC systems having rated voltages up to 1 000 V AC or up to 1 500 V DC. These devices are fixed or portable. They are intended to be used indoors and/or outdoors. Power metering and monitoring devices (PMD)@ as defined in this document@ give additional safety information@ which aids the verification of the installation and enhances the performance of the distribution systems. The power metering and monitoring devices (PMD) for electrical parameters described in this document are used for general industrial and commercial applications. This document does not address functional safety and cyber security aspects. This document is not applicable for: electricity metering equipment that complies with IEC 62053-21@ IEC 62053-22@ IEC 62053-23 and IEC 62053-24. Nevertheless@ uncertainties defined in this document for active and reactive energy measurement are derived from those defined in IEC 62053 (all parts) the measurement and monitoring of electrical parameters defined in IEC 61557-2 to IEC 61557-9 and IEC 61557-13 or in IEC 62020 power quality instrument (PQI) according IEC 62586 (all parts) devices covered by IEC 60051 (all parts) (direct acting analogue electrical measuring instrument). NOTE 1 Generally such types of devices are used in the following applications or for the following general needs: energy management inside the installation@ such as facilitating the implementation of documents such as ISO 50001 and IEC 60364-8-1 monitoring and/or measurement of electrical parameters measurement and/or monitoring of the quality of energy inside commercial/industrial installations. NOTE 2 A measuring and monitoring device of electrical parameters usually consists of several functional modules. All or some of the functional modules are combined in one device. Examples of functional modules are: measurement and monitoring of several electrical parameters simultaneously energy measurement and/or monitoring@ as well as sometimes compliance with aspects of building regulations alarms functions demand side quality (current and voltage harmonics@ over/under voltages@ voltage dips and swells@ etc.). NOTE 3 PMD are historically called power meter@ power monitor@ power monitor device@ power energy monitoring device@ power analyser@ multifunction meter@ measuring multifunction equipment@ energy meters. NOTE 4 Metering@ measuring and monitoring applications are explained in Annex A.

3Version History

IEC 61557-12:2007 older 2007-08
IEC 61557-12:2018/AMD1:2021 Amd 1/2021 newer 2021-05-21
IEC 61557-12:2021 newer 2021-05-21
IEC 61557-12:2018/COR1:2022 Cor 1/2022 newer 2022-09-12

6Frequently Asked Questions

What is IEC 61557-12:2018?
IEC 61557-12:2018 — Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 12: Power metering and monitoring d is an international standard developed by International Electrotechnical Commission (IEC). This part of IEC 61557 specifies requirements for power metering and monitoring devices (PMD) that measure and monitor the electrical quantities within electrical distribution systems@ and optionally other external signals. These requirements also...
What does IEC 61557-12:2018 cover?
This standard covers: This part of IEC 61557 specifies requirements for power metering and monitoring devices (PMD) that measure and monitor the electrical quantities within electrical distribution systems@ and optionally other external signals. These requirements also define the performance in single- and three-phase...
Who should use this standard?
This standard is intended for organizations, professionals, and stakeholders involved in various industries and sectors. It is applicable to manufacturers, service providers, regulatory bodies, and certification organizations.
What is the latest version of IEC 61557-12:2018?
The current published version is IEC 61557-12:2018, published on 2018-10-22. Always check for amendments or pending revisions.
How do I purchase IEC 61557-12:2018?
You can purchase IEC 61557-12:2018 by visiting our contact page. Click "Get This Standard" to view pricing and send a purchase inquiry. Our team will respond with payment and delivery details.